Ransburg® Voltage Controller (RVC)

Combine with the RansFlex Automatic Gun for Ultimate Electrostatic Coating

Easily access and control your power supply with the RVC — Ransburg® Voltage Controller. The RVC can support two RansFlex automatic guns with independent or linked control for ultimate adaptability and convenience. Power is right at your fingertips.

Ransburg RVC Voltage Controller - Carlisle Fluid Technology
  • Overview
  • Tech Specs
  • Literature
  • Product Manuals
  • Materials
  • Markets
  • Part Numbers
Overview

Product Overview Icon - Carlise FTOverview

Based on proven Ransburg® voltage-generation technology, the RVC automatically detects the hardware as soon as it is connected. An intuitive touch screen with plug and play capabilities allows for easy operation, advanced troubleshooting and fast access to data easily retrieved by USB. While older controllers often require constant upgrades in order to work effectively, the RVC’s innovative design eliminates the need for frequent updates. It provides reliability and control for ultimate applicator transfer efficiency, less maintenance, improved coverage and maximum safety.

  • Full color touch screen display
  • Advanced on-screen troubleshooting with event history log 
  • Lifetime usage and process-based data analytics 
  • Independent or linked control of up to two RansFlex automatic guns from a single controller 
  • Data retrieval via front USB port

Complete solutions for an ideal finish 

Ransburg® manual and automatic electrostatic finishing products offer spray finishing solutions to industrial and automobile manufacturing markets. Utilizing electrostatic spray painting technology, our products deliver a “Class A” finish to each and every customer’s project.

The brands you trust 

Ransburg® is part of the complete family of industrial finishing solutions collectively known as CFT. Under the global leadership of Carlisle Fluid Technologies, the CFT family line provides total system solutions for your application needs. 

Technical Specifications

Technical Specifications

Ransburg® Voltage Controller (RVC)

Environmental/Physical
Operating Temperature: 5°C to +40°C (41°F to +104°F)
Storage and Shipping Temperature: -40°C to +85°C (-40°F to +185°F) (Allow power supply to reach room temperature before use)
Humidity: 95% Non-Condensing
Height: 18.4 cm (7.3 inches)
Width: 27.3 cm (10.8 inches)
Depth: 39.4 cm (15.5 inches)
Weight: 10.2 kg (22.5 lbs.)
Electrical
Input Voltage: 100-240 VAC
Frequency: 50-60 Hz
Current: 1 A max. RMS
Wattage: 75 watts (max.)
Output Voltage: Dependent upon applicator
RansFlex Automatic: 1-65kV MAX DC, adjustable in 1kV increments
Ground: Use known good earth ground

Ransburg® RansFlex RFXA Automatic Gun

Environmental/Physical
Tubing Requirements  
    Atomizing Air: 5/16” (8 mm) OD Nylon
    Fan Air: 5/16” (8 mm) OD Nylon
    Trigger Air 5/32” (4 mm) OD Nylon
Applicator Length: 273 mm (10.75”)
Weight: (Without Hose) 1050 grams (37 oz.)
Low Voltage Cable 79338-XX Lengths (Std): 10 m, 15 m, 20 m and 30 m
Electrical
Operating Voltage: 65kV DC (-) maximum
Current Output: 90 microamperes maximum
Paint Resistance:* .1 MΩ to ∞
Part Sprayability: Determine sprayability of part to be coated using 76652, Test Equipment

* Use Model No. 76652, Test Equipment (See current “Paint, HV & SCI Test Equipment” service manual TE-98-01)

Mechanical
Fluid Flow Capacity: 1000 mL/minute**
Wetted Parts: Stainless, polyethylene, nylon, acetal polymer
Operating Pressure (Air Spray)  
    Fluid: (0-6.9 bar) 0-100 psi
    Air: (0-6.9 bar) 0-100 psi
    Trigger: (5.5-6.9 bar) 80-100 psi
Ambient Temperature: 40˚C to 5˚C (104˚F to 41˚F)
Trigger Response Time: 150 msec open and close

** This reflects the maximum fluid volume the applicator can deliver. The maximum spray volume that can be effectively atomized depends on fluid rheology, spray technology and finish quality required.

Literature

Literature

 - Carlisle Fluid Technology

Literature for the Ransburg® Voltage Controller (RVC)

Show literature
Ransburg® Voltage Controller (RVC) - French - Carlisle Fluid Technology

Ransburg® Voltage Controller (RVC) - French

Literature for the Ransburg® Voltage Controller (RVC) in French

Show literature
Ransburg® Spannungsregler (RVC) - Carlisle Fluid Technology

Ransburg® Spannungsregler (RVC)

Literatur für den Ransburg®-Spannungsregler (RVC)

Show literature
Controlador de tensión Ransburg® (RVC) - Carlisle Fluid Technology

Controlador de tensión Ransburg® (RVC)

Literatura para el Controlador de tensión Ransburg® (RVC)

Show literature
Ransburg® Voltage Controller (RVC) - Italian - Carlisle Fluid Technology

Ransburg® Voltage Controller (RVC) - Italian

Literature for the Ransburg® Voltage Controller (RVC) in Italian

Show literature
Ransburg® Güç Kontrol Ünitesi (RVC) - Carlisle Fluid Technology

Ransburg® Güç Kontrol Ünitesi (RVC)

Ransburg® Güç Kontrol Ünitesi (RVC) için literatür

Show literature
Ransburg® Voltage Controller (RVC) - Carlisle Fluid Technology

Ransburg® Voltage Controller (RVC)

Literatura dotycząca kontrolera napięcia Ransburg® (RVC)

Show literature
Ransburg® Voltage Controller (RVC) - Russian - Carlisle Fluid Technology

Ransburg® Voltage Controller (RVC) - Russian

Literature for the Ransburg® Voltage Controller (RVC) in Russian

Show literature
Product Manuals

Product Manuals

Manual for Ransburg RV - English - Carlisle Fluid Technology

Manual for Ransburg RV - English

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - French - Carlisle Fluid Technology

Manual for Ransburg RV - French

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - German - Carlisle Fluid Technology

Manual for Ransburg RV - German

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - Spanish - Carlisle Fluid Technology

Manual for Ransburg RV - Spanish

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - Italian - Carlisle Fluid Technology

Manual for Ransburg RV - Italian

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - Russian - Carlisle Fluid Technology

Manual for Ransburg RV - Russian

Service manual for the Ransburg RV CP-19-01

Show literature
Manual for Ransburg RV - Chinese - Carlisle Fluid Technology

Manual for Ransburg RV - Chinese

Service manual for the Ransburg RV CP-19-01

Show literature
RansFlex RFXA Electrostatic Automatic Spray Gun Service Manuals (AA-17-01) - Carlisle Fluid Technology

RansFlex RFXA Electrostatic Automatic Spray Gun Service Manuals (AA-17-01)

Service Manual for RansFlex RFXA Electrostatic Automatic Spray Gun

Show literature
RansFlex RFXAW Electrostatic Automatic Spray Gun Service Manual (AA-18-02) - Carlisle Fluid Technology

RansFlex RFXAW Electrostatic Automatic Spray Gun Service Manual (AA-18-02)

Service Manual for RansFlex RFXAW Electrostatic Automatic Spray Gun

Show literature
Ransburg RansFlex Auto Placemat IL-450 Solv Non-Bleed - Carlisle Fluid Technology

Ransburg RansFlex Auto Placemat IL-450 Solv Non-Bleed

RansFlex RFXA Solvent Non Bleed Electrostatic Automatic Spray Gun Placemat

Show literature
Ransburg RansFlex Auto Placemat IL-451 Solv Bleed - Carlisle Fluid Technology

Ransburg RansFlex Auto Placemat IL-451 Solv Bleed

RansFlex RFXA Solvent Bleed Electrostatic Automatic Spray Gun Placemat

Show literature
Ransburg RansFlex RFXAW Water Non Bleed - Carlisle Fluid Technology

Ransburg RansFlex RFXAW Water Non Bleed

RansFlex RFXAW Water Non Bleed Electrostatic Automatic Spray Gun Placemat

Show literature
Ransburg RansFlex Auto Placemat IL-449 Water Bleed - Carlisle Fluid Technology

Ransburg RansFlex Auto Placemat IL-449 Water Bleed

RansFlex RFXAW Water Bleed Electrostatic Automatic Spray Gun Placemat

Show literature
Materials

Materials

For use on the materials below:

  • Metal
  • Wood
  • Plastic
  • Ceramic
  • Other Substrates
  • Primer
  • Base Coat
  • Clear Coat
Markets

Markets

  • General Industry
Part Numbers

Part Numbers

Ransburg RV, 81000-01000