Ransburg RMA-560 Robot Mounted Dual Purge Direct

The RMA-560 is an automatic RMA capable of spraying solvent borne coatings electrostatically or non-electrostatically.

It incorporates the latest in high speed spindle technology, bell cup and shape air design to provide the best in atomization and pattern control.

Ransburg RMA-560 Robot Mounted Dual Purge Direct - Carlisle Fluid Technology
  • Overview
  • Tech Specs
  • Literature
  • Product Manuals
  • Materials
  • Markets
  • Part Numbers
Overview

Product Overview Icon - Carlise FTOverview

True dual purge capability...

spray one color while cleaning the other paint line with no loss of tip voltage.

Proven long life turbine and bell cup...

capable of speeds up to 100,000 rpm, achieving optimum atomization and versatility for today’s coatings.

Warranty...

proven components - 3 year or 15,000 hour warranty.

No external high voltage cable...

the internally mounted high voltage cascade requires only low voltage control wiring.

Less waste to the spray booth...

with the dump valve located internally next to the feed tube.

Color coded tubing bundle...

for easy change-outs and operational efficiency.

The RMA-560 is an automatic robot mounted rotary atomizer capable of spraying solvent borne coatings electrostatically or non-electrostatically. It incorporates the latest in high speed spindle technology, bell cup and shape air design to provide the best in atomization and pattern control. The bell cups are designed for durability and all wetted components are designed to offer the maximum in wear and chemical resistance.  The RMA-560 incorporates an integrated turbine allowing speeds up to 100,000 rpm, dependent on the coating flowrate.

The RMA-560’s heavy duty design insures excellent service life even when subjected to the quick motions of robotic applications. Components are constructed of durable engineered resins for optimum mechanical strength and solvent resistance. The bells aerodynamic shape and light weight package allows better maneuverability into tight spaces and provides ease of cleaning of the external surfaces. The easily removable front and rear shrouds, turbine assembly and the internally mounted fluid valves, make off-line maintenance more efficient and economical. An optional split shroud is available for easy access to internal components while still mounted on the robot. The new construction also reduces downtime for maintenance, utilizing the quick disconnect feature an atomizer can be changed in less than two minutes.

Technical Specifications

Technical Specifications

Ransburg RMA-560 Robot Mounted Dual Purge Direct

Electrical Specifications

Power Supply Type MicroPak 2e
Charging Method Direct
Operating Voltage 30-100 kV Variable (100 kV Maximum)
Output Current 125 μA
Turbine Speed Control MicroPak 2e

Mechanical Specifications

Weight Automizer only: 12.77 lbs. (5.8 Kg) max.
Turbine Type Air Bearing Impulse Drive
Turbine Air Supply Variable; Maximum/Minimum Up to 100,000 rpm (dependent on Turbine Speed: air flow rate)
Tubing Bundle Max. Rotation 450° in Either Direction
Bearing Air Supply at the Applicator 90 psig (±10 psi) (Nominal): (621 kPa ±69 kPa) 2.9 SCFM (82 slpm)
Brake Air Supply 60-100 psig (414-689 kPa)
Maximum Paint Fluid Pressure Supply 200 psi (1379 kPa)
Maximum Solvent Fluid Pressure Supply 150 psi (1035 kPa)
Fluid Flow Rates 25-1000 cc/min. (dependent on bell cup size, speed and flow rates) Available in 30mm, 55mm and 65mm.
Literature

Literature

Ransburg RMA 500 Series Rotary Atomizers Sales Literature - Carlisle Fluid Technology

Ransburg RMA 500 Series Rotary Atomizers Sales Literature

Sales Literature for RMA 500 Series Rotary Atomizers

Show literature
Ransburg RMA-560 Dual/Single Direct Sales Literature - Carlisle Fluid Technology

Ransburg RMA-560 Dual/Single Direct Sales Literature

Sales Literature for RMA-560 Dual/Single Direct

Show literature
Ransburg Bell Comparison Sheet - Carlisle Fluid Technology

Ransburg Bell Comparison Sheet

Comparison sheet for Ransburg Bell

Show literature
Product Manuals

Product Manuals

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Ransburg RMA-560 Single/Dual Model A13364 Service Manual - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Model A13364 Service Manual

Service Manual for RMA-560 Single/Dual Model A13364

Show literature
Ransburg RMA Dual Purge Direct MODEL: A12868 Service Manual - Carlisle Fluid Technology

Ransburg RMA Dual Purge Direct MODEL: A12868 Service Manual

Service Manual for RMA Dual Purge Direct MODEL: A12868

Show literature
Ransburg Test Stand Service Manual - Carlisle Fluid Technology

Ransburg Test Stand Service Manual

Service Manual for Test Stand

Show literature
Ransburg Robust High Speed Turbine Rebuild/Inspection - Carlisle Fluid Technology

Ransburg Robust High Speed Turbine Rebuild/Inspection

Service Instruction for Robust High Speed Turbine Rebuild/Inspection

Show literature
Inner Shape Air Assembly (A12874) service manual - English - Carlisle Fluid Technology

Inner Shape Air Assembly (A12874) service manual - English

Service manual for RMA 303 & 500 Series Applicators

Show literature
Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual FR - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual FR

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual DE  - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual DE

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual IT  - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual IT

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual ES - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual ES

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual RU - Carlisle Fluid Technology

Ransburg RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782 Service Manual RU

Service Manual for RMA-560 Single/Dual Purge Direct Charge ATEX Model: A13782

Show literature
Materials

Materials

For use on the materials below:

  • Metal
  • Wood
  • Plastic
  • Ceramic
  • Other Substrates
  • Primer
  • Basecoat
  • Clearcoat
Markets

Markets

  • Automotive OEM & Tier 1&2
Part Numbers

Part Numbers

Part Numbers A12868, A13782, A13364