Ransburg MicroPak 2e Power Supply
In conjunction with a Ransburg cascade, is used to provide high voltage for electrostatic equipment.
The system uses a combination of proven high voltage generation technology, including microprocessor-base control with diagnostic and communication functions.

Overview
Ultimate in Operational Safety...
protections include over voltage, over current, DI/DT and DV/DT.
Simplified controls...
a user friendly control panel makes it easy to operate and change settings.
Simplified installation...
the new stand alone, compact unit greatly reduces cost and installation time.
Ethernet IP communication...
designed for use in process control.
The Ransburg MicroPak 2e, in conjunction with a Ransburg cascade, is used to provide high voltage for electrostatic equipment. The system uses a combination of proven high voltage generation technology, including microprocessor-base control with diagnostic and communication functions.
The unit is available in a compact, stand-alone unit or single component that easily slides into a euro-rack or control system. The MicroPak 2e’s simplified controls and user-friendly control panel make it easy to control the high voltage, applicator speed and pneumatic I/O of a single applicator, while easily interfacing with PLC hardware. The MicroPak 2e is the perfect companion for Ransburg applicators; Aerobell, Aerobell 33, Aerobell 168, Evolver SE, TurboDisk or RMA applicators.
Technical Specifications
Ransburg MicroPak 2e Power Supply
Physical Specifications
Operating Temperature | 0°C to +55°C |
Humidity | 95% Non-Condensing |
Physical Size | 5.1” tall X 8.5” wide X 6.5” deep |
Power Required (Per Controller)
Controller | 24V DC @ 0.5 Amps |
Cascade | 24V DC @ 6.0 Amps (fully loaded output), RansPak 1000 (RP1000) Cascade 24V DC @ 2.0 Amps (fully loaded output), HP404, RP404, HP505, A12760 and A12761 Cascades |
High Voltage Power | 24 Volts, 10Amp, Form C relay contact |
Discrete In | (Dry Contact) Remote Stop Misc IO Interlock/Trigger Door Interlock Booth Air Interlock (Analog) KV Setpoint (0-10VDC) |
Discrete Out | (3, Dry Contact) Interlock Out External Power Enable System Alarm Controller Operating Range |
High Voltage | 0-100kV, settable in 1kV increments Communication Requirements |
Control and Reporting | EtherNet/IP |
HP404/RP404 Cascade Output | 100 kV @ 0 μA 125 μA @ 0 kV |
RP1000 Cascade Output | 100 kV @ 0 μA 1000 μA @ 0 kV |
Literature

Ransburg MicroPak 2e High Voltage Controller Sales Literature
Sales Literature for MicroPak 2e High Voltage Controller
Show literature
Product Manuals

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - English
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - English
Service Manual for MicroPak 2e Single Bell Control (Model A13613)
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - English
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Fiber Optic Transceiver (LN-9628) - English
Service Manual for Ransburg Fiber Optic Transceiver (MODEL: 80629-02)(LN-9628)
Show literature
Ransburg Micropak 2e - Service Manual (SI-17-04) - English
Service Manual for Micropak 2e - Array Member Configuration Setting (SI-17-04)
Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - French
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - German
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Italian
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Spanish
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Russian
Service Manual for MicroPak 2E Controls
Show literature
Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - German
Service Manual for MicroPak 2e Single Bell Control (Model A13613)
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - German
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - French
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Spanish
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Italian
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Russian
Service Manual for MicroPak 2E Custom Integration Kit
Show literature
Materials
For use on the materials below:
- Metal
- Wood
- Plastic
- Ceramic
- Other Substrates
- Primer
- Basecoat
- Clearcoat
Markets
Part Numbers
Part Numbers | A13613 |
Ransburg MicroPak 2e Power Supply
MICROPAK 2e SINGLE BELL CONTROLLER - PARTS LIST |
|
Part # |
Description |
A13338-XX XX XX XX |
MICROPAK 2E HV & ATOMIZER CONTROLLER FOR REPLACEMENT USE, THE USER SHOULD ORDER THE SAME MODEL (-XXXXXXXX) THAT WAS LISTED ON THE ORIGINAL INVOICE. |
A13245-00 |
MICROPAK 2E HIGH VOLTAGE CONTROLLER PC BOARD - ATOMIZER CONTROL |
A13248-00 |
MICROPAK 2E ANALOG OUTPUT, 4-20MA ADD-ON BOARD |
A11111-00 |
VOLUME BOOSTER, 1:1 |
78643-00 |
E/P TRANSDUCER, HIGH SPEED, HIGH FLOW, DIN RAIL MOUNT, 0-10V : 0-100PSI |
A11485-00 |
PNEUMATIC SOLENOID, MINIMUM 4MM BORE, 0-120 PSI |
A13596 |
PRESSURE TRANSDUCER, 0-100 PSI : 0-10V |
MICROPAK 2e HIGH VOLTAGE CONTROLLER - PARTS LIST |
|
Part No. |
Description |
A13338-XXXXXXXX |
MicroPak 2e HV & Atomizer Controller For replacement use, the user should order the same model number (-XXXXXXXX) listed on the original invoice. |
A13245-X1 |
MicroPak 2e Multi-Function Board, “X” indicates quantity of A13248-00 boards included |
A13248-00 |
MicroPak 2e Analog Output, 4-20mA add-on board |
A11111-00 |
Volume Booster, 1:1 |
78643-00 |
E/P Transducer, High Speed, High Flow, DIN Rail Mount, 0-10V : 0-100PSI |
A11485-01 |
Pneumatic Solenoid, minimum 4mm bore, 0-120 PSI |
A13596 |
Pressure Transducer, 0-100 PSI : 0-10V |
A13245-X8 |
MicroPak 2e Multi-Function Board, Discrete I/O configuration. “X” indicates quantity of A13248-00 boards included. |