Ransburg MicroPak 2e Power Supply - Carlisle Fluid Technology
  • Overview
  • Tech Specs
  • Literature
  • Product Manuals
  • Materials
  • Markets
  • Part Numbers
Overview

Product Overview Icon - Carlise FTOverview

Ultimate in Operational Safety...

protections include over voltage, over current, DI/DT and DV/DT.

Simplified controls...

a user friendly control panel makes it easy to operate and change settings.

Simplified installation...

the new stand alone, compact unit greatly reduces cost and installation time.

Ethernet IP communication...

designed for use in process control.

The Ransburg MicroPak 2e, in conjunction with a Ransburg cascade, is used to provide high voltage for electrostatic equipment. The system uses a combination of proven high voltage generation technology, including microprocessor-base control with diagnostic and communication functions.

The unit is available in a compact, stand-alone unit or single component that easily slides into a euro-rack or control system. The MicroPak 2e’s simplified controls and user-friendly control panel make it easy to control the high voltage, applicator speed and pneumatic I/O of a single applicator, while easily interfacing with PLC hardware. The MicroPak 2e is the perfect companion for Ransburg applicators; Aerobell, Aerobell 33, Aerobell 168, Evolver SE, TurboDisk or RMA applicators.

Technical Specifications

Technical Specifications

Ransburg MicroPak 2e Power Supply

Physical Specifications

Operating Temperature 0°C to +55°C
Humidity 95% Non-Condensing
Physical Size 5.1” tall X 8.5” wide X 6.5” deep

Power Required (Per Controller)

Controller 24V DC @ 0.5 Amps
Cascade 24V DC @ 6.0 Amps (fully loaded output), RansPak 1000 (RP1000) Cascade 24V DC @ 2.0 Amps (fully loaded output), HP404, RP404, HP505, A12760 and A12761 Cascades
High Voltage Power 24 Volts, 10Amp, Form C relay contact
Discrete In (Dry Contact) Remote Stop Misc IO Interlock/Trigger Door Interlock Booth Air Interlock (Analog) KV Setpoint (0-10VDC)
Discrete Out (3, Dry Contact) Interlock Out External Power Enable System Alarm Controller Operating Range
High Voltage 0-100kV, settable in 1kV increments Communication Requirements
Control and Reporting EtherNet/IP
HP404/RP404 Cascade Output 100 kV @ 0 μA 125 μA @ 0 kV
RP1000 Cascade Output 100 kV @ 0 μA 1000 μA @ 0 kV
Literature

Literature

Ransburg MicroPak 2e High Voltage Controller Sales Literature - Carlisle Fluid Technology

Ransburg MicroPak 2e High Voltage Controller Sales Literature

Sales Literature for MicroPak 2e High Voltage Controller

Show literature
Product Manuals

Product Manuals

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00)  - English - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - English

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - English - Carlisle Fluid Technology

Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - English

Service Manual for MicroPak 2e Single Bell Control (Model A13613)

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - English - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - English

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Fiber Optic Transceiver (LN-9628) - English - Carlisle Fluid Technology

Fiber Optic Transceiver (LN-9628) - English

Service Manual for Ransburg Fiber Optic Transceiver (MODEL: 80629-02)(LN-9628)

Show literature
Ransburg Micropak 2e - Service Manual (SI-17-04) - English - Carlisle Fluid Technology

Ransburg Micropak 2e - Service Manual (SI-17-04) - English

Service Manual for Micropak 2e - Array Member Configuration Setting (SI-17-04)

Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - French - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - French

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - German - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - German

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Italian - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Italian

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Spanish - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Spanish

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Russian - Carlisle Fluid Technology

Ransburg MicroPak 2E Controls Service Manual (LN-9624-00) - Russian

Service Manual for MicroPak 2E Controls

Show literature
Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - German - Carlisle Fluid Technology

Ransburg MicroPak 2e Single Bell Control (Model A13613) Service Manual (LN-9625-00 ) - German

Service Manual for MicroPak 2e Single Bell Control (Model A13613)

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - German - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - German

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - French - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - French

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Spanish - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Spanish

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Italian - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Italian

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Russian - Carlisle Fluid Technology

Ransburg MicroPak 2E Custom Integration Kit Service Manual (LN-9627-00) - Russian

Service Manual for MicroPak 2E Custom Integration Kit

Show literature
Materials

Materials

For use on the materials below:

  • Metal
  • Wood
  • Plastic
  • Ceramic
  • Other Substrates
  • Primer
  • Base Coat
  • Clear Coat
Markets

Markets

Part Numbers

Part Numbers

Part Numbers A13613

 

Ransburg MicroPak 2e Power Supply

 

MICROPAK 2e SINGLE BELL CONTROLLER - PARTS LIST

Part #

Description

A13338-XX XX XX XX

MICROPAK 2E HV & ATOMIZER CONTROLLER FOR REPLACEMENT USE, THE USER SHOULD ORDER THE SAME MODEL (-XXXXXXXX) THAT WAS LISTED ON THE ORIGINAL INVOICE.

A13245-00

MICROPAK 2E HIGH VOLTAGE CONTROLLER PC BOARD - ATOMIZER CONTROL

A13248-00

MICROPAK 2E ANALOG OUTPUT, 4-20MA ADD-ON BOARD

A11111-00

VOLUME BOOSTER, 1:1

78643-00

E/P TRANSDUCER, HIGH SPEED, HIGH FLOW, DIN RAIL MOUNT, 0-10V : 0-100PSI

A11485-00

PNEUMATIC SOLENOID, MINIMUM 4MM BORE, 0-120 PSI

A13596

PRESSURE TRANSDUCER, 0-100 PSI : 0-10V

 

MICROPAK 2e HIGH VOLTAGE CONTROLLER - PARTS LIST

Part No.

Description

A13338-XXXXXXXX

MicroPak 2e HV & Atomizer Controller

For replacement use, the user should order the same model number (-XXXXXXXX) listed on the original invoice.

A13245-X1

MicroPak 2e Multi-Function Board, “X” indicates quantity of A13248-00 boards included

A13248-00

MicroPak 2e Analog Output, 4-20mA add-on board

A11111-00

Volume Booster, 1:1

78643-00

E/P Transducer, High Speed, High Flow, DIN Rail Mount, 0-10V : 0-100PSI

A11485-01

Pneumatic Solenoid, minimum 4mm bore, 0-120 PSI

A13596

Pressure Transducer, 0-100 PSI : 0-10V

A13245-X8

MicroPak 2e Multi-Function Board, Discrete I/O configuration. “X” indicates quantity of A13248-00 boards included.